Every compressed air system leaks – the only questions are how much and at what cost. According to KAESER KOMPRESSOREN, even a new, well-maintained network loses around 15–20% of the air it produces, and in older installations losses easily reach 30–40%. That is air you pay electricity for, but which does no useful work.

Why leaks are so expensive

  • Energy paid for, then lost. The compressor produces the escaping air and consumes power for it around the clock whenever the network is pressurised.
  • Pressure drop. Leaks consume flow that your machines need. The usual reaction is to raise compressor pressure – and at higher pressure every leak loses even more air.
  • Longer compressor run times. More hours under load mean more frequent service intervals and shorter equipment life.

What a single leak costs

KAESER calculated the annual cost of a single leak for continuous operation (8,760 h/year), an electricity price of €0.30/kWh and a specific package power of 6.0 kW per m³/min:

PressureLeak Ø 1 mmLeak Ø 2 mmLeak Ø 3 mm
4 bar€710€2,823€6,307
6 bar€1,025€3,942€8,515
8 bar€1,340€5,203€12,457

Source: KAESER KOMPRESSOREN. At a different electricity price the values change proportionally.

For your own system use the formula:

Annual leakage cost = leakage (m³/min) × specific power (kW per m³/min) × operating hours × electricity price (€/kWh)

How to find out how much air you lose

The simplest method is a measurement during a production stop. With all consumers switched off and the network pressurised, the compressor keeps cycling only because of leaks. Measure its total load time over a fixed period (e.g. 30–60 minutes):

Leakage ≈ compressor flow rate × (load time ÷ total measuring time)

If a 5 m³/min compressor runs on load for 12 of 60 minutes, leakage is about 1 m³/min – air you pay for but never use. Master controllers such as SIGMA AIR MANAGER collect this data automatically.

Where leaks usually hide

  • Quick couplings, fittings and hoses at points of use
  • Air preparation units (filter-regulator-lubricator)
  • Threaded joints and flanges, especially in old galvanised pipework
  • Timer-controlled condensate drains that discharge air along with condensate – level-controlled electronic drains (such as KAESER ECO-DRAIN) discharge condensate only
  • Pneumatic tools and cylinders with worn seals

Detect, repair, repeat

  1. Detect. Ultrasonic leak detectors find leaks during operation, without stopping production. Each leak is tagged and its location and approximate size are recorded in a report.
  2. Repair by priority. You don’t have to fix everything at once. According to KAESER, fixing the largest 20% of leaks often cuts total leakage by 80% or more. The goal is to bring losses below 10% of the air produced.
  3. Repeat. New leaks appear all the time – checks should be a regular part of maintenance, not a one-off campaign.

Related articles

Need help?

MAVA Industrial is the official representative of KAESER KOMPRESSOREN in Bulgaria. Contact us for advice on your compressed air system – call 0800 40 007 (free of charge in Bulgaria) or write to info@mavaindustrial.com.

Sources:

  • KAESER KOMPRESSOREN – Leak management: detection is half the battle (kaeser.com)
  • KAESER Compressors – Fix air leaks and improve your bottom line (us.kaeser.com)