Every compressed air system leaks – the only questions are how much and at what cost. According to KAESER KOMPRESSOREN, even a new, well-maintained network loses around 15–20% of the air it produces, and in older installations losses easily reach 30–40%. That is air you pay electricity for, but which does no useful work.
Why leaks are so expensive
- Energy paid for, then lost. The compressor produces the escaping air and consumes power for it around the clock whenever the network is pressurised.
- Pressure drop. Leaks consume flow that your machines need. The usual reaction is to raise compressor pressure – and at higher pressure every leak loses even more air.
- Longer compressor run times. More hours under load mean more frequent service intervals and shorter equipment life.
What a single leak costs
KAESER calculated the annual cost of a single leak for continuous operation (8,760 h/year), an electricity price of €0.30/kWh and a specific package power of 6.0 kW per m³/min:
| Pressure | Leak Ø 1 mm | Leak Ø 2 mm | Leak Ø 3 mm |
|---|---|---|---|
| 4 bar | €710 | €2,823 | €6,307 |
| 6 bar | €1,025 | €3,942 | €8,515 |
| 8 bar | €1,340 | €5,203 | €12,457 |
Source: KAESER KOMPRESSOREN. At a different electricity price the values change proportionally.
For your own system use the formula:
Annual leakage cost = leakage (m³/min) × specific power (kW per m³/min) × operating hours × electricity price (€/kWh)
How to find out how much air you lose
The simplest method is a measurement during a production stop. With all consumers switched off and the network pressurised, the compressor keeps cycling only because of leaks. Measure its total load time over a fixed period (e.g. 30–60 minutes):
Leakage ≈ compressor flow rate × (load time ÷ total measuring time)
If a 5 m³/min compressor runs on load for 12 of 60 minutes, leakage is about 1 m³/min – air you pay for but never use. Master controllers such as SIGMA AIR MANAGER collect this data automatically.
Where leaks usually hide
- Quick couplings, fittings and hoses at points of use
- Air preparation units (filter-regulator-lubricator)
- Threaded joints and flanges, especially in old galvanised pipework
- Timer-controlled condensate drains that discharge air along with condensate – level-controlled electronic drains (such as KAESER ECO-DRAIN) discharge condensate only
- Pneumatic tools and cylinders with worn seals
Detect, repair, repeat
- Detect. Ultrasonic leak detectors find leaks during operation, without stopping production. Each leak is tagged and its location and approximate size are recorded in a report.
- Repair by priority. You don’t have to fix everything at once. According to KAESER, fixing the largest 20% of leaks often cuts total leakage by 80% or more. The goal is to bring losses below 10% of the air produced.
- Repeat. New leaks appear all the time – checks should be a regular part of maintenance, not a one-off campaign.
Related articles
- How properly sized is your compressed air system? (Part 1)
- Selecting the right air receiver (Part 3)
- Selecting the right piping network (Part 4)
Need help?
MAVA Industrial is the official representative of KAESER KOMPRESSOREN in Bulgaria. Contact us for advice on your compressed air system – call 0800 40 007 (free of charge in Bulgaria) or write to info@mavaindustrial.com.
Sources:
- KAESER KOMPRESSOREN – Leak management: detection is half the battle (kaeser.com)
- KAESER Compressors – Fix air leaks and improve your bottom line (us.kaeser.com)